Step 1 - turn off 24vac supply power
at source.
Step 2 - open cover, loosen screws &
disconnect sensor wires from connector on right side.
Step 3 - attach calibration key to
sensor connection of the circuit you are calibrating and
tighten screws. (Top connector for right side, bottom for
left)
Step 4 - turn on 24vac supply at
source.
Step 5 - switch auto/manual switch up
to auto (Right switch for top, left switch for bottom)
Step 6 - adjust blue “Threshold” on
same circuit (top for right side, bottom for left)
Counter-clockwise until red Milk light is lit.
Step 7 - press reset/start button and
turn “Threshold” clockwise until red Milk light is blinking
at same rate as green Run light.
Step 8 - adjust other circuit in the
same manner if required.
Step 9 - turn off 24vac supply at
source.
Step 10 - unscrew & remove
calibration key (store in box)
Step 11 - reconnect sensor wires and
tighten screws.
Step 12 - secure cover, turn on power
& test unit for proper operation.
Step 1: while unit is in operation
(on cow & working) toward end of cycle, if unit is coming
off too soon turn “Threshold” 1/4 to 1/2 turn
counter-clockwise and run the unit while milking another cow
on it.
Step 2 : if unit detaching too late
turn “Threshold 1/4 to 1/2 turn clockwise until red Milk
light extinguishes and unit comes off eight seconds later.